Decommissioning

12.1
Switching off the pump and tem-
porary shutdown
12.2

Shutdown and storage

Installation and operating instructions • Wilo-Stratos GIGA, Wilo-Stratos GIGA B • Ed.01/2023-05
Type Symbol
Values/explanations
OFF
Pump kick is switched off
Can be set between 2 h and 72 h in 1 h
±
steps
Can be set between the pump's minimum
±
and maximum speeds
For additional information, see "Acknow-
±
ledging errors" section.
Access disable inactive (changes possible)
±
(for additional information, see section "Ac-
tivating/Deactivating access disable").
Access disable active (no changes possible)
(for additional information, see "Activating/
Deactivating access disable" section)
CAUTION
Risk of property damage due to overheating!
Hot fluids can damage the pump seals when the pump is at a standstill.
After deactivating the heat source:
• Allow the pump to run until the fluid temperature has dropped to an
CAUTION
Risk of property damage due to frost!
If there is a danger of frost:
• Drain the pump completely to avoid damage.
Close the shut-off device in the pressure pipe. If a non-return valve is installed in the
pressure pipe, and there is counter pressure, the shut-off device can remain open.
Do not close the shut-off device in the suction line.
Switch off the pump and allow it to drain completely. Ensure the coasting is smooth.
If there is no danger of frost, make sure the fluid level is sufficient.
Operate the pump every month for 5 minutes. Doing this prevents deposits from occur-
ring in the pump compartment.
WARNING
Risk of injury and damage to property!
• Dispose off the pump contents and rinsing fluid by taking the legal
• Always wear protective clothing, safety gloves and safety glasses
Clean the pump thoroughly prior to storage!
Drain the pump completely and rinse thoroughly.
The remaining fluid and rinsing fluid should be drained, collected and disposed off via
the drain plug. Observe local regulations along with the notes under "Disposal"!
Seal suction and discharge connection with caps.
After removal, store the pump in a dry, dust-free location.
appropriate level.
regulations into account.
when working.
Display conditions
Not displayed if pump kick was de-
activated
Not displayed if pump kick was de-
activated
Only displayed if there is an error.
en
141

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Stratos giga b

Inhaltsverzeichnis