5.3

Scope of delivery

5.4

Accessories

6

Description of the pump

6.1

Design

Fig. 3: Views of Stratos GIGA
Fig. 4: Views of Stratos GIGA B
Installation and operating instructions • Wilo-Stratos GIGA, Wilo-Stratos GIGA B • Ed.01/2023-05
solids, oils or EPDM-attacking substances in the fluid,
Air in the system, etc.
NOTICE
The flow value shown on the IR Stick's display or that is output to the
building management system must not be used to control the pump.
This value is merely an indicator of general trends.
A flow value is not output on every pump type.
Always observe the safety data sheet for the fluid to be pumped!
Pump
Installation and operating instructions
Accessories must be ordered separately:
Stratos GIGA:
3 mounting brackets with fixation material for installation on a base
Stratos GIGA B:
Supports for installation on a base or baseplate
IR-Stick
IF module PLR for connecting to PLR/interface converter
IF module LON for connection to the LONWORKS network
IF module BACnet
IF module Modbus
CAN IF module
Wilo-Smart IF module
DDG kit
For a detailed list, consult the catalogue and spare parts documentation.
NOTICE
IF modules may only be plugged in when the pump is de-energised
(voltage-free).
The Wilo-Stratos GIGA high-efficiency pumps are glanded pumps with built-in power ad-
justment and "Electronic Commutated Motor" (ECM) technology. The pumps are designed
as single-stage low-pressure centrifugal pumps with flange connection and mechanical
seal.
Stratos GIGA version
The pump housing has an in-line design, i.e. the flanges on the suction and discharge sides
lie along a centre line. All pump housings are equipped with cast-on pump feet. Installation
on a base is recommended for units with a rated power of ≥ 5.5 kW and above.
Stratos GIGA B version
Spiral housing pump with dimensions in accordance with DIN EN 733.
All pump housings are equipped with cast-on pump feet. From motor power ≥ 5.5 kW: Mo-
tors with cast or screwed-on feet.
Installation on a base is recommended for units with a rated power of ≥ 5.5 kW and above.
en