98
Property
Electromagnetic compatib-
1)
ility
Interference emission in acc.
with:
Interference immunity in
acc. with:
2)
Sound-pressure level
3)
Permissible fluids
3)
Permissible fluids
Electrical connection
Internal electric circuit
Speed control
Relative humidity
1)
This product is a professional device within the meaning of EN 61000-3-2.
2)
Mean value of the sound-pressure levels on a spatial cuboid measuring surface at a dis-
tance of 1 m from the pump surface in accordance with DIN EN ISO 3744.
3)
For additional information on permissible fluids, see "Fluids".
4)
For motor powers of 11 ... 22 kW, electronic modules for IT networks are optionally
available. Compliance with the specified values in accordance with EN 61800-3 can only
be guaranteed for the standard version of TN/TT networks. Non-observance can result in
EMC faults.
Table 2: Technical data
Additional information
Permissible fluids
CH
Heating pumps
Heating water
(in accordance with VDI 2035/VdTÜV Tch 1466/CH: in ac-
cordance with SWKI BT 102-01)
...
No oxygen binding agents, no chemical sealants (ensure
closed system from corrosion perspective according to VDI
2035 (CH: SWKI BT 102-01); rework leaky points).
Note that water-glycol mixtures or fluids with a viscosity different than that of clean water
increase the power consumption of the pump. Only use mixtures with corrosion protection.
Observe the relevant manufacturer's specifications!
The fluid must be sediment-free.
Wilo's approval must be obtained for the use of other fluids.
Mixtures with a glycol content > 10% influence the flow calculation.
When using water-glycol mixtures, the use of an S1 variant with a corresponding mech-
anical seal is generally recommended.
For state-of-the-art systems, compatibility of the standard (mechanical) seal with the
fluid can be assumed under normal system conditions.
Special circumstances may require special seals, for example:
Installation and operating instructions • Wilo-Stratos GIGA, Wilo-Stratos GIGA B • Ed.01/2023-05
Value
EN 61800-3:2018-09
EN 61800-3:2018-09
L
< 83 dB (A) ⃒ ref. 20 µPa Depending on pump type
pA,1 m
Heating water in accordance
with VDI 2035 part 1 and
part 2
Cooling/cold water
Water-glycol mixture to 40%
vol.
Water-glycol mixture to 50%
vol.
Heat carrier oil
Other fluids (on request)
3~380 V -5% +10% 50/60 Hz
3~400 V ±10%, 50/60 Hz
3~440 V, ±10%, 50/60 Hz
PELV, galvanically isolated
Built-in frequency converter
For T
= 30 °C:
environment
90%, non-condensing
For T
= 40 °C:
environment
60%, non-condensing
Note
Residential environment
(C1)
Industrial environment (C2)
Standard version
Standard version
Standard version
Special version only
Special version or auxiliary
equipment (at additional
charge)
Supported mains types: TN,
4)
TT, IT

Werbung