Drive Test GmbH München
10 APPENDIX
10.1 ERROR MESSAGES DISPLAY UNIT
Display
Service
E:0x
Protocol error
E:1x
Serial interface error (x: Bit0=Parity, Bit1=Framing, Bit2=Overflow)
E:18
Baudrate error
E:20
Sensor connector change
E:21
Wrong sensor (version conflict)
E:30
Sensor supply error
Bit0=IES invalid, Bit1=IES instable, Bit2=DMS invalid, Bit3=DMS instable, Bit4=timeout
C:xx
xx format is decimal, has to be converted into binary format
E:31
Missing measure data (Time Out)
E:32
Low Bat
E:40
LCD - test error
n
Number of successfully tests
E:41
SRAM memory fast test error
n
Number of successfully tests
E:42
SRAM memory test error
3:xx
Hexadecimal number of errors MSB
2:xx, 1:xx
..
0:xx
Hexadecimal number of errors LSB
E:43
EEPROM test error
nn
Number of error bytes
E:44
EEPROM system parameter initialisation error
nn
Number of error bytes
E:45
EEPROM test error sensor data
nn
Number of error bytes
E:46
EEPOROM initialisation error sensor data
nn
Number of error bytes
E:47
A/D-converter does not react
n
Number of successful tests
E:48
Real Time Clock does not react
C:00
Data line constantly 0
C:01
Data line constantly 1
E:50
Message Queue overflow
E:51
Queue for schedule data overflow
E:52
Queue for long term messages overflow
E:53
System died (Watchdog)
E:54
Stack overflow
E:55
Serial transmit data overflow
E:60
Bus arbitration error
C:xx
Demanding client
B:xx
Actual bus activity
E:70
Overflow force measure data
E:71
Overflow position measure data
E:80
Access violation SRAM
C:01
memory address invalid
C:02
Bloc length invalid
C:03
Bloc out of valid range
C:04
SRAM-address invalid
C:05
SRAM-length invalid
C:06
SRAM-overflow
C:07
Align – error
E:81
Access violation at EEPROM
C:0x
Error code, see E:80
E:82
Memory Access violation
C:0x
Error code, see E:80
E:88
EEPROM does not react (not busy)
C:0x
0 = system parameter, 1 = sensor data
E:89
EEPROM does not react no longer (constantly busy)
C:0x
0 = system parameter, 1 = sensor data
E:8A
Denied write access on EEPROM for sensor data
E:FF
Error cause unknown
(*) with service button additional error code is available
Version 7.1
Handbuch / Manual FM200
Meaning
Seite 97 von 99
Archive: FM200_DE_EN_V7.1