7.10
Domestic hot water comfort function (pre-
heating)
models have a "domestic hot water com-
UNIQA REVOLUTION 25
fort" function which ensures the best performance in terms of
domestic hot water, reducing the time necessary for the hot wa-
ter to become available and ensuring that the temperature is
stable.
To activate the function:
– select parameter "PAR 22" (see "Parameter setting and dis-
play") and set it to a 1
– exit parameter settings and press button
5 seconds until the symbol
gins to flash indicating that the function has been activated.
To deactivate the function:
– press button
>
again for approximately 5 seconds until the
symbols
r
and
R
appear on the display and begin to flash
indicating that the function has been deactivated.
42
>
for approximately
r