7.5
Display of operating data and counters
Once the boiler is operating a qualified technician can view the
operating data and the counters as follows:.
From the operating screen in the mode enabled at that moment
(WINTER
n
or SUMMER
– go into "DISPLAY" by pressing the buttons
for more than 3 seconds until the following screen
same time
appears
From this point, the technician has 2 options:
– scroll through the list of "information (PAR)" and "counters
by pressing the button
(PARc)"
– display the "activated alarms" (no more than 10) by pressing
the button
r
– Once in this section, proceed with button
When all the values have been displayed, exit the menu by
pressing and holding down the button
seconds until the initial screen is displayed.
36
l
):
r
and
t
. Scrolling will be in sequence
t
or
r
.
y
for approximately 5
TABLE OF INFORMATION DISPLAYED
Type
No.
PAR
00
PAR
01
PAR
02
PAR
03
PAR
04
PAR
05
PAR
06
PAR
07
<
at the
PAR
08
PAR
09
PAR
10
PAR
11
TABLE OF COUNTER DISPLAYED
Type
No.
PAR
c0
PAR
c1
PAR
c2
PAR
c3
PAR
c4
PAR
c5
PAR
c6
TABLE OF ACTIVATED ALARMS/FAULTS
Type
No.
PAR
A0
PAR
A1
PAR
A2
PAR
A3
PAR
A4
PAR
A5
PAR
A6
PAR
A7
PAR
A8
PAR
A9
Description
Range
SW version
External sensor
- 9 .. 99
Delivery sensor 1
- 9 .. 99
temperature
Delivery sensor 2
- 9 .. 99
temperature
Domestic hot water
- 9 .. 99
sensor temperature
Air inlet probe (SIA)
- 9 .. 99
display
Par. 13
Actual heating SET
... Par.
temperature
14
Power level
0 .. 99
Flow meter rate
0 .. 99
Water pressure
transducer reading
0...99
(if resent)
Return probe
0 .. 99
display
Compressor (CP)
ON/
status
OFF
Description
Range
total no. of boiler
0 .. 99
h x 1000
operating hours
total no. of burner
0 .. 99
h x 1000
operating hours
total no. of burner
0 .. 99
h x 1000
ignitions
total no. faults
0 .. 99
total no. of times
PAR parameters
0 .. 99
accessed
total no. of times
OEM parameters
0 .. 99
accessed
time until next
maintenance
0 .. 99
months
intervention
Description
Last activated alarm/fault
Last but one activated alarm/fault
Third from last activated alarm/fault
Previous activated alarm/fault
Previous activated alarm/fault
Previous activated alarm/fault
Previous activated alarm/fault
Previous activated alarm/fault
Previous activated alarm/fault
Previous activated alarm/fault
U/M
Step
°C
1
°C
1
°C
1
°C
1
°C
1
°C
1
%
1
l/min
0.1
bar
0.1
°C
1
U/M
Step
0.1; from
0.0 to 9.9;
1; from 10
to 99
0.1; from
0.0 to 9.9;
1; from 10
to 99
0.1; from
0.0 to 9.9;
1; from 10
to 99
x 1
1
x 1
1
x 1
1
1