5.1.3 - VP: Pressure display

Plant pressure measured in [bar] or [psi] depending on the measuring system used.

5.1.4 - VF: Flow display

Displays the instantaneous flow in [litres/min] or [gal/min] depending on the set measuring system. If the recorded measurement is below the
sensitivity threshold of the flow sensor, the measurement value flashes next to the VF identification.

5.1.5 - PO: Absorbed power display

Power absorbed by the electropump in [kW].
If the maximum allowed power is exceeded, the measurement flashes next to the PO identification.

5.1.6 - C1: Phase current display

Motor phase current in [A].
If the maximum allowed current is exceeded, the identification C1 blinks, indicating an imminent tripping of the overload protection.
5.1.7 - SV
: Supply voltage
Present only in some models.
5.1.8 - SR
: Supply range
Present only in some models.
Indicates the range of supply voltage found. It may have the values: [110-127] V or [220-240] V. If the range is not determined, it has the value "- -".

5.1.9 - TE: Dissipator temperature display

5.1.10- PKm
: Pressure measured at intake
Present only in models with Kiwa function

5.1.11 - Operating hours and number of starts

Indicates on three lines the hours that the device has been powered up, the pump working hours and the number of starts of the motor.

5.1.12 - PI: Power histogram

A histogram of the power delivered is displayed on 5 vertical bars. The histogram indicates how long the pump has been on at a given power
level. On the horizontal axis are the bars at the various power levels; on the vertical axis, the time for which the pump has been on at the specific
power level (% of the time with respect to the total).
Figure 17.2: Power histogram display
(2)
Figure 17.1: Power histogram display
(1)

5.1.13 - Output flow meter

The page shows two flow meters. The first shows the total output flow delivered by the machine. The second shows a partial count and can be
reset by the user. The partial count can be reset from this page, by holding down the " ˅ " button for 2 sec.

5.1.14 - NT: Display of network configuration

(2)
Information on network and serial connectors. The serial connector can be displayed in full by pressing the "^" key.

5.1.15 - VE: Version Display

Information on the hardware version, serial number and mac address of the pump.
5.1.16 - FF: Fault & Warning display (Log)
Chronological display of the faults that have occurred during system operation. Under the symbol FF appear two numbers x/y indicating
respectively the ault displayed and the total number of faults present; to the right of these numbers is an indication of the type of fault displayed.
The ˄ and ˅ keys scroll through the list of faults: pressing the ˅ key goes back through the log and stops at the oldest fault present, pressing the
˄ key goes forward in the log and stops at the most recent fault. The faults are displayed in chronological order starting from the one that appeared
farthest back in time x=1 to the most recent x=y. The maximum number of faults that can be shown is 64; when that number is reached, the log
starts to overwrite the oldest ones. This item on the menu displays the list of faults, but does not allow reset. Reset can be carried out only with
50