The pump does not start.
The pump does not stop.
Insufficient delivery
The pump starts without
utility request.
The water pressure when
turning on the utility is not
immediate.
When the utility is turned
on the flow falls to zero
before the pump starts
The display shows BL
The display shows BP1
The display shows BP2
The display shows OC
The display shows PB

12. UPDATING THE FIRMWARE

Firmware version 3.xx can only be updated via App, for other versions the update can be done via D-connect Box through wireless communication.
For further information on the latter type of update please refer to the D-Connect Box manual.

13. DISPOSAL

This product or its parts must be disposed of in an environment-friendly manner and in compliance with the local regulations concerning the
environment; use public or private local waste collection systems.

14. GUARANTEE

Any use of faulty material or manufacturing defects of the appliance will be eliminated during the guarantee period contemplated by the law in
force in the country where the product is purchased, by repair or replacement, as we decide.
The guarantee covers all substantial defects that can be assigned to manufacturing faults or to the material used if the product has been used
correctly, in accordance with the instructions.
The guarantee is void in the following cases:
• attempts to repair the appliance,
• technical alterations to the appliance,
• use of non original spare parts,
• tampering,
• inappropriate use, for example industrial use.
When making a request under guarantee, apply to an authorised technical assistance service, presenting proof of purchase of the product.
Red: off
Utility at a level higher than
White: on
the system restarting pressure
Blue: off
level (par. 3.2).
1. Leak in the system.
2. Impeller or hydraulic part
Red: off
clogged.
White: on
3. Air getting into the suction
Blue: off
pipe.
4. Faulty flow sensor
1. Suction depth too high.
Red: off
White: on
2. Suction pipe clogged or
Blue: off
diameter insufficient.
3. Impeller or hydraulic part
clogged.
Red: off
1. Leak in the system.
White: on
2. Faulty non-return valve.
Blue: off
Red: off
Expansion vessel empty
White: on
(insufficient air pressure) or
Blue: off
has broken diaphragm.
Red: off
Air pressure in the expansion
White: on
vessel higher than the system
Blue: off
starting pressure.
1. No water.
Red: on
2. Pump not primed.
White: on
3. Setpoint not reachable
Blue: off
with the set RM value
Red: on
White: on
Faulty pressure sensor.
Blue: off
Red: on
White: on
Faulty pressure sensor.
Blue: off
Red: on
1. Excessive absorption.
White: on
2. Pump blocked.
Blue: off
Red: on
1. Supply voltage too low.
White: on
2. Excessive drop in voltage
Blue: off
on the line.
ENGLISH
Increase the system restarting pressure level by increasing SP or
decreasing RP.
1. Check the system, find and eliminate the leak.
2. Dismantle the system and remove the obstructions (assistance
service).
3. Check the suction pipe, find and eliminate the cause of air getting in.
4. Contact the assistance centre.
1. As the suction depth increases the hydraulic performance of the product
decreases. Check whether the suction depth can be reduced. Use a suction
pipe with a larger diameter (but never smaller than 1").
2. Check the suction pipe, find the cause of choking (obstruction, dry bend,
counterslope, ...) and remove it.
3. Dismantle the system and remove the obstructions (assistance service).
1. Check the system, find and eliminate the leak.
2. Service the non-return valve as described in par. 9.3.
Check the air pressure in the expansion vessel. If water comes out when
checking, the vessel is broken: assistance service. Otherwise restore the
air pressure according to the equation par. 1.2.
TCalibrate the expansion vessel pressure or configure the parameters SP
and/or RP so as to satisfy the equation par.1.2.
1-2. Prime the pump and check whether there is air in the pipe. Check
whether the suction or any filters are blocked.
3. Set a RM value that allows the setpoint to be reached.
Contact the assistance centre.
Contact the assistance centre.
1. Fluid too dense. Do not use the pump for fluids other than water.
2. Contact the assistance centre.
1. Check the presence of the correct supply voltage.
2. Check the section of the power supply cables.
Excluded from the guarantee:
• parts subject to rapid wear.