The system is suitable for treating drinking water.
The system cannot be used to pump salt water, sewage, inflammable, corrosive or explosive liquids (e.g. petroleum, petrol,
thinners), greases, oils or food productsi.
The system can suck up water with a level that does not exceed the depth of 8 m (he height between the water level and the
pump suction mouth).
If the system is used for the domestic water supply, respect the local regulations of the authorities responsible for the
management of water resources.
When choosing the installation site, check that:
• The voltage and frequency on the pump's technical data plate correspond to the values of the power supply system.
• The electrical connection is made in a dry place, far from any possible flooding.
The earth system must comply with the regulations.
The possible presence of a small amount of water inside the product is a residue of the testing process.
If you are not sure of the absence of foreign bodies in the water to be pumped, install a filter on the system intake that is suitable for catching
impurities.
The installation of a filter on intake causes a decrease of the system's hydraulic performance proportional to the loss of load caused
by the filter itself (generally the greater the filtering power, the greater the fall in performance).
Choose the type of configuration you intend to use (vertical or horizontal) considering the connections to the system, the position of the user
interface panel, and the spaces available according to the indications below. Wall installation is possible, see par. 8.2.

2.1 - Vertical Configuration

Screw the 4 rubber feet supplied loose in the package into the brass
seats in face C. Put the system in place, taking into account the
dimensions in Fig.6.
• The distance of at least 10mm between Face E of the system and any
wall is obligatory to ensure ventilation through the grids provided. If
you expect to have to drain the system from its discharge door and
not from the system, leave a further distance sufficient to manoeuvre
the drainage cap.
• The distance of at least 10mm between Face B of the system and
an obstruction is obligatory to let out the power supply cable to the
mains socket.
The distance of at least 200mm between Face A of the system
and an obstruction is recommended so as to be able to remove
the door and gain access to the technical compartment.
If the surface is not flat, unscrew the foot that is not touching and adjust its height until it contacts the surface so as to ensure the stability of the
system. The system must in fact be placed in a safe and stable position, ensuring that its axis is vertical: it must not be in an inclined position.

2.1.1 Hydraulic connections

Make the connection at input to the system through the mouth on Face F marked "IN" in. Fig.6 (suction connection). Then remove the cap using
a screwdriver.
Make the connection at output from the system through the mouth on Face F marked "OUT" in Fig.6 (delivery connection). Then remove the cap
using a screwdriver.
All the hydraulic connections of the system to the plant to which it can be connected are of the threaded female type 1" GAS, made of brass.
If you intend to connect the product to the plant with fittings that have a diameter larger than the normal 1" pipe (for example
the ring nut in the case of fittings in 3 pieces), make sure that the 1" Gas male thread of the coupling protrudes at least 25mm
from the above diameter (see Fig.7)
ENGLISH
40