Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Data; Appendix; Accessories - Emerson AVENTICS AES PROFINET IO Serie Systembeschreibung

Ventiltreiber av
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Malfunction
Possible cause
The new module is not recog-
nized.
RUN/BF LED illuminated red
Severe network error present Check network
IP address assigned twice
RUN/BF LED flashes red
Connection to master has
been disrupted. PROFINET IO
communication can no
longer take place.
An error was discovered in
the PLC configuration.
L/A 1 or L/A 2 LED illuminated
No data exchange with the
in green
bus coupler, e.g. because the
(only seldom yellow flashing)
network section is not con-
nected to a controller.
Bus coupler was not config-
ured in the controller.
L/A 1 or L/A 2 LED is off
There is no connection to a
network participant.
The bus cable is defective and
no connection can be made
with the next network partici-
pant.
The other network partici-
pant is defective.
Bus coupler is defective.
See also
2 Table of malfunctions [} 43]

14 Technical Data

Table 24: Technical data
General data
Dimensions
Weight
Operating temperature range
Storage temperature range
Ambient operating conditions
Vibration resistance
Shock resistance
Protection class according to EN60529/
IEC60529
Relative humidity
Degree of contamination
Use
Table 25: Technical data
Electronics
Electronics power supply
Actuator voltage
Valve inrush current
Rated current for both 24 V power supplies
Connections
Table 26: Technical data
BUS
Bus protocol
AVENTICS™ AES PROFINET IO | R412018140-BAL-001-AI | English
Remedy
Please contact one of our ad-
dresses (see back cover for
contact data).
Change the IP address.
Check the connection to the
master.
Check the PLC configuration.
Connect the network section
with a controller.
Configure bus coupler in the
controller.
Connect fieldbus connection
X7E1 or X7E2 with a network
participant (e.g. a switch).
Exchange the bus cable.
Exchange network partici-
pant.
Exchange the bus coupler.
37.5 mm x 52 mm x 102 mm
0.17 kg
-10°C to 60°C
-25°C to 80°C
Max. height above sea level: 2000 m
Wall mounting EN 60068-2-6:
• ±0.35 mm displacement at 10 Hz to 60
Hz,
• 5 g acceleration at 60 Hz to 150 Hz
Wall mounting EN 60068-2-27:
• 30 g with 18 ms duration,
• 3 shocks each direction
IP65 with assembled connections
95%, non condensing
2
Only in closed rooms
24 V DC ±25%
24 V DC ±10%
50 mA
4 A
Power supply for bus coupler X1S:
• Plug, male, M12, 4-pin, A-coded
Functional earth (FE)
• Connection according to
DIN EN 60204-1/IEC60204-1
PROFINET IO
BUS
Connections
Output data quantity
Input data quantity
Standards and directives
DIN EN 61000-6-2 "Electromagnetic compatibility" (Immunity for industrial environments)
DIN EN 61000-6-4 "Electromagnetic compatibility" (Emission standard for industrial envi-
ronments)
DIN EN 60204-1 "Safety of machinery – Electrical equipment of machines – Part 1:
General requirements"

15 Appendix

15.1 Accessories

Table 27: Accessories
Description
Plug, CN2 series, male, M12x1, 4-pin, D-coded, 180° straight cable
exit, for fieldbus line connection X7E1/X7E2
• Max. line that can be connected: 0.14 mm
• Ambient temperature: -25°C to 85°C
• Nominal voltage: 48 V
Socket, CN2 series, female, M12x1, 4-pin, A-coded, 180° straight ca-
ble exit, for power supply connection X1S
• Max. line that can be connected: 0.75 mm
• Ambient temperature: -25°C to 90°C
• Nominal voltage: 48 V
Socket, CN2 series, female, M12x1, 4-pin, A-coded, 90° angled cable
exit, for power supply connection X1S
• Max. line that can be connected: 0.75 mm
• Ambient temperature: -25°C to 90°C
• Nominal voltage: 48 V
Protective cap M12x1
Retaining bracket, 10x
Spring clamp element, 10x, including assembly instructions
Left end plate
Right end plate for stand-alone variant
Fieldbus connections X7E1 and X7E2:
• Socket, female, M12, 4-pin, D-coded
Max. 512 bits
Max. 512 bits
Mat. no.
R419801401
2
(AWG26)
8941054324
2
(AWG19)
8941054424
2
(AWG19)
1823312001
R412018339
R412015400
R412015398
R412015741
44

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis