movements must be limited. They must not exceed a 40° angle from the vertical axis passing through the anchor point of the fall arrest
device. ⑧ It is recommended not to suddenly drop the cable or strap when it is unwinding. It is best to accompany it back into the casing.
This operation is very important. If it is not respected the cable can go out his guide. ⑦ During use, the overall system must not be in
contact with: cutting elements, sharp edges and structures of small diameter, oils, harsh chemicals, fire, hot metal, all types of electrical
conductors... May provide a protective sheath. ►For safety reasons and before each use, check: That the fall indicator (located on the
swivel) is not triggered (the red color must not appear). / that the connectors (EN362) are closed and locked / that the operating
instructions described for each component of the system are met / that the general disposition of the work situation reduces the fall risk,
the drop height and the pendulum movement in the case of a fall. / that the vertical clearance is sufficient (free space beneath the feet of
the user) and no obstacles disrupt the normal functioning of the fall arrest system. it is essential for safety to verify the free space required
beneath the user at the workplace before each occasion of use, so that, in the case of a fall, there will be no collision with the ground or
other obstacle in the fall path.
deflection of the anchorage device. - The maximum deflection of the carabiners. - The elongation of the linking system. - The maximum
stretch of the body supporting device. - The anchorage location relative to where the user is when a fall occurs. - The height of the user.
Additionally, a safety distance of 1 m is added to obtain the vertical clearance value.
recommendations for use for each component of the system.
linking system. Fall arrest distance = H value (See reference table)
ground or other objects in the event of a fall.
hazard. WARNING ! It is essential for your safety that work is carried out in a manner so as to minimize the risk of falls as well as the
height of the fall.
► Unless otherwise indicated, the fall arrest device must not be used in the "HORIZONTAL USE" configuration (See
reference table) WARNINGS: The device's anchorage point must always be located above or level with the work surface. The
attachment point must be located above the user and the work carried out in such a way, as to minimize both the potential for falls and
potential fall distance. AN106 , AN130 : ⑨ HORIZONTAL USE : The device has been successfully tested for horizontal use. Horizontal
use is the configuration in which the fall arrest device is attached to an anchor point at the sternal or dorsal harness attachment point
level (factor 1).
The device has been tested successfully for a fall over a Type A edge. A steel bar with a radiusr = 0,5mm with no burs
was used for this test. On the basis of this test, the device is suitable for use over similar edges such as rolled steel profiles, wooden
beams or a clad, proof parapet.However, the following shall be considered when the equipment is used in a horizontal or transverse
arrangement and a risk of a fall from a height over an edge exists: If the risk assessment carried out before the start of work shows that
the edge is very sharp and/ or degraded can degrade the cable or strap: - Appropriate measures must be taken before starting work to
prevent a fall from the edge or, - install protection on the falling edge or, - contact the manufacturer.
situated at the same height or above as the edge at which a fall might occur. The required clearance below the edge at which a fall might
occur shall be defined.
To limit this pendulum movement, the work area or the lateral movements must be limited. They must not
exceed 1,50 m on either side of the axis perpendicular to the edge (from which the drop can occur) and passing through the anchor point
of the fall arrest device. If the work situation requires that these limits be exceeded, the individual anchor point is not the appropriate
device. Use a type C or D anchor device according to the standard EN795:2012 (example: a lifeline). Warning : EN795-C:2012 & EN795-
D:2012 : This device cannot be used with an anchoring device of this type.
account to determine the required clearance. For this purpose, the information specified in the instructions for use of the anchorage
device must be considered. After a fall over an edge, there is a risk of injuries caused by impact against the building or c onstruction.
Warning : In case of a fall over the edge, special rescue measures shall be defined and trained. AN106 : ⑮ Factor 2 use (See reference
table) : Factor 2 use is the configuration in which the fall arrest device is attached to an anchor point under the user's feet. ▪TECHNICAL
CHARACTERISTICS (See reference table) : - Materials: (PART 4). WARNING ! AN106 : Strap high density polyethylene (UHMWPE) :
Low melting point. (140°) Usage limits: Before any PPE implementation operation, set up a rescue plan to deal with any emergency that
may occur during the operation.
absorbers etc...): maximum life of 10 years from date of manufacture.
can cause it to vary greatly: -Non-compliance with the manufacturer's instructions for transport, storage and use /-"Aggressive" work
environment: marine atmosphere, chemicals, extreme temperatures, sharp edges... /-Particularly intensive use /-Shock or significant
constraint /-Disregard for the product item's history. Warning: these factors can cause damage invisible to the naked eye. ►Warning:
certain extreme conditions can shorten the shelf life by a few days. ▪In the case of doubt or if the device was used to stop a fall, it must
be immediately withdrawn from use and returned to the manufacturer or any competent person appointed by them. ▪If in doubt, always
remove the product for it to undergo either: - a review /- destruction. The shelf life is not a substitute for periodic verification (minimum
annually) which will assess the condition of the product.
WWW.DELTAPLUS.EU.
manufacturer nor without using their procedures. Existing components must not be replaced nor must other components be added.
not use beyond the area of use defined in the instructions for use. The manufacturer cannot be held liable for any direct or indirect
accident after a modification or use other than that provided in this manual. Do not use this equipment beyond its limits. ▪To ensure its
working condition and therefore the safety of the user, the product must be checked systematically:
points: State of the cable: no start of rupture of one or more threads, no folding, no burning, no corrosion or oxidation, no deformation of
the cable stranding. / State of the strap or rope: no fraying, no boot cut, no visible damage at seams, no burning and no unusual narrowing.
/Condition of seams and fasteners: no visible damage . /
thermoplastic film or the textile sheath and strap). / Condition of the metal parts: no wear, no deformation, no corrosion or oxidation. /
General condition: look for any possible damage due to ultraviolet radiation and other climatic conditions / Correct operation and locking
of connectors . / That the fall indicator (located on the swivel) is not triggered (the red color must not appear). / Correct operation of the
retractable function and cable or strap lock. Test the blocking device of the reel in/out of the cable or strap by taping out. Maintain the
blocked position and release the tension to see if the cable or strap returns in the device./ Specific conditions such as humidity, snow,
ice, mud, dirt, paint, oil, glue, corrosion, wear of the strap or rope, etc..., can significantly reduce the operation of the fall arrest device.
►2 / in the following cases: Before and during use / if in doubt / In the case of contact with chemicals, solvents or fuels that could affect
operation. / If it has been subjected to stress during a previous fall. / At least every twelve months by the manufacturer or a competent
organization, mandated by them.
by the manufacturer or a competent organization, mandated by them. This very important check is related to the maintenance and
efficacy of the PPE and hence the user's safety. This check must be carried out in strict compliance with the manufacturer's periodic
examination procedures. A written document authorising reuse should be obtained during this audit in order to reuse the PPE. This
document will clarify that the user's safety is linked to maintaining the efficiency and resistance of the equipment.
the PPE if necessary. ►In accordance with European regulations, the identification form must be completed prior to the first use of the
product and then updated and kept with the product as well as the manual by the user. ►The readability of the product labelling must
be checked periodically. It is very important to do this operation, to check all components and assembly inside the product, and to be
sure about the correct functioning. ►FALL INDICATOR: When the fall indicator is activated, the red color appears (or the green color
disappears in the case of the T connector) : do not use the fall arrest device. Have the fall arrest device inspected and checked the by
the manufacturer or a competent organization, mandated by them. The fall indicator swivel must be replaced. In these cases, follow the
instructions described in their own manual. ►WARNINGS: The user's safety depends on the continuing efficacy of the PPE, its strength
and the proper understanding of the instructions in this manual. Any static or dynamic overload may damage the PPE. The weight of
the user, including his clothing and equipment must not exceed the maximum weight indicated on the fall arrest. ▪WARNINGS: Do not
4
DELTA PLUS GROUP - ZAC La Peyrolière - BP140 - 84405 APT Cedex - France - Tel: +33 (0) 4
90 74 20 33 - Fax: +33 (0) 4 90 74 32 59 - www.deltaplus.eu
The vertical clearance depends on different factors, but not limited to, it includes: - The maximum
Provide a safe distance from the ground and the power lines or areas with an electrical
▪ SHELF LIFE:
►Textile products or those containing textile elements (harnesses, belts, shock
▪No modification or addition or repair of the PPE may be made without prior written consent from the
▪ PERIODIC REVIEW of PPE: ►An examination must be performed at least every twelve months
AN100, AN102, AN105, AN106, AN130 (EN360) : The elongation of the
Ensure that proper fall clearance exists in order to prevent striking
The deviation of the anchorage device must be taken into
►The shelf life is given as an indication. The following factors
►TO FIND YOUR LOCAL ANNUAL REVIEW CENTRE, VISIT
That the shock absorber is not triggered (start of tear or tearing of the
For the different factors, refer to the
The anchor point may only be
►1 / visually inspect the following
►Repair or replace
UPDATE 21/07/2021