Blue: off
The water pressure when
Red: off
turning on the utility is not
White: on
immediate.
Blue: off
When the utility is turned
Red: off
on the flow falls to zero
White: on
before the pump starts.
Blue: off
Red: on
The display shows BL
White: on
Blue: off
Red: on
The display shows BP1
White: on
Blue: off
Red: on
The display shows OC
White: on
Blue: off
Red: on
The display shows PB
White: on
Blue: off
Red: off
The display shows: Press
White: on
^ to propagate this config
Blue: off
ENGLISH
2. Faulty non-return valve.
Expansion
vessel
empty
(insufficient air pressure) or
has broken diaphragm.
Air pressure in the expansion
vessel higher than the system
starting pressure.
1. No water.
2. Pump not primed.
3. Setpoint not reachable with
the set RM value
1. Faulty pressure sensor.
1. Excessive absorption.
2. Pump blocked.
1. Supply voltage too low.
2. Excessive drop in voltage
on the line.
One or more devices have
sensitive
parameters
not
aligned.
Table 22 Solving typical problems
80
2. Service the non-return valve as described in paragraph 12.3.
Check the air pressure through the valve in the technical compartment. If
water comes out when checking, the vessel is broken: assistance service.
Otherwise restore the air pressure according to the equation (par. 1.4).
Calibrate the expansion vessel pressure or configure the parameters SP
and/or RP so as to satisfy the equation (par. 1.4).
1-2 Prime the pump and check whether there is air in the pipe. Check
whether the suction or any filters are blocked.
3. Set a RM value that allows the setpoint to be reached.
1. Contact the assistance centre.
1. Fluid too dense. Do not use the pump for fluids other than water.
2. Contact the assistance centre.
1. Check the presence of the correct supply voltage.
2. Check the section of the power supply cables.
Press the ^ key on the device which we are sure has the most recent and
correct configuration of the parameters.