8.3.1
SP: Setting the setpoint pressure
Pressure at which the system is pressurised: min 1.0 bar (14 psi) - max 12.0 bar (174 psi)
8.3.2
Setting the auxiliary pressures
The device has the possibility of varying the setpoint pressure according to the status of the inputs, up to 4 auxiliary pressures can be set for a
total of 5 different setpoints. For the electrical connections refer to the control unit manual. ; For the software settings see paragraph 9.6.15.3 -
Setting the auxiliary point input function.
If several auxiliary pressure functions associated with several inputs are active at the same time, the device will set the lowest
pressure of all the active ones.
The auxiliary setpoints can be used only through the control unit.
8.3.2.1
P1: Setting the auxiliary setpoint 1
Pressure at which the system is pressurised if the auxiliary setpoint
function is activated on input 1.
8.3.2.2 P2: Setting the auxiliary setpoint 2
Pressure at which the system is pressurised if the auxiliary setpoint
function is activated on input 2.
8.3.2.3 P3: Setting the auxiliary setpoint 3
Pressure at which the system is pressurised if the auxiliary setpoint
function is activated on input 3.
8.3.2.4 P4: Setting the auxiliary setpoint 4
Pressure at which the system is pressurised if the auxiliary setpoint
function is activated on input 4.
The pump restarting pressure is linked not only to the set pressure (SP, P1, P2, P3, P4) but also to RP. RP expresses the
decrease in pressure, with respect to "SP" (or to an auxiliary setpoint if activated), caused by the pump starting.
Example: SP = 3.0 [bar]; RP = 0.3 [bar]; no active auxiliary setpoint function: During normal operation the system is pressurised at
3.0 [bar]. The electropump restarts when the pressure falls below 2.7 [bar].
Setting a pressure (SP, P1, P2, P3, P4) that is too high for the pump performance may cause false water lack errors BL; in these
cases lower the set pressure.

8.4 Manual Menu

From the main menu, hold down simultaneously the "SET" and "^" and "˅"keys until the manual menu page appears (or use the selection menu
pressing ^ or ˅).
The menu allows you to view and modify various configuration parameters: the MODE key allows you to scroll through the menu pages, the ^
and ˅ keys allow you respectively to increase and decrease the value of the parameter concerned. Press SET to leave this menu and return to
the main menu. Entering the manual menu by pressing the SET ^ ˅ keys puts the machine into forced STOP condition. This function can be
used to force the machine to stop. In manual mode, irrespective of the parameter displayed, it is always possible to perform the following
controls:
Temporary starting of the electropump
Pressing the MODE and ^ keys at the same time causes the pump to start at speed RI and this running status remains as long as the two keys
are held down.
When the pump ON of pump OFF command is given, a communication appears on the display.
Starting the pump
Holding down the MODE ˅ ^ keys simultaneously for 2 sec. causes the pump to start at speed RI. The running status remains until the SET key
is pressed. The next time the SET key is pressed the pump leaves the manual menu. When the pump ON of pump OFF command is given, a
communication appears on the display. In case of operation in this mode for more than 5' with no flow of liquid, an alarm overheating alarm will
be triggered, with the error PH shown on the display. Once the PH error condition is no longer present, the alarm will be reset automatically
only. The reset time is 15'; if the PH error occurs more than 6 times consecutively, the reset time increases to 1h.
Once it has reset further to this error, the pump will remain in stop status until the user restarts it using the "MODE" "˅" "^"keys.