en
18 | 1 687 010 399 | Product description
3.5.5
Hose line 1 680 712 312
For CRI with connector (Denso).
Fig. 7:
Hose line 1 680 712 312
1 680 712 312
Fig. 8:
Hose line 1 680 712 312
1 Lever for hose retainer
2 O-ring 1 680 210 129 (Ø4 x 1.5)
1. Press down on lever (Fig. 8, Pos. 1).
2. Insert hose line 1 680 712 312 into the return of the
CRI.
3. Release lever (Fig. 8, Pos. 1). The hose retainer must
engage in the groove of the return connection.
4. Connect hose line 1 680 712 312 to hose line
1 680 712 289.
|
1 689 989 196
2016-10-03
3.5.6
Adapter cable for electrical connection of Delphi CRIs.
Fig. 9:
3.5.7
Adapter cable for electrical connection of CRI with flat
pin contacts, e.g. Denso (see Fig. 11, Pos. 1).
Fig. 10:
1
2
1
2
458812-14
Fig. 11:
1 Injector
2 Connection socket with pin contacts
Adapter cable 1 684 465 844
FD...
1 684 465 844
Adapter cable 1 684 465 844
Adapter cable 1 684 465 679
FD...
1 684 465 679
Adapter cable 1 684 465 679
Denso injector
458826_4pa
458826_5pa
Robert Bosch GmbH