General Description; Preparation Before Use; Checking The Oil Level - SDMO neo 3000 Benutzer- Und Wartungshandbuch

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 35
1.3.12 Safety guidelines for handling batteries
Danger

2. General description

Earth connection (no.1)
Inspection cover (no.2)
Fuel tap (no.3)
Fuel tank aeration pointer (no.4)
Fuel tank cap (no.5)
Choke (no.6)
Recoil starter (no.7)
Electrical socket (no.8)
Inspection trap cover (no.1)
Fuel tank aeration pointer RUN
Tank pressurisation pump (no.2)
Fuel strainer (no.3)
Maximum fuel filling level
Air filter cover (no.1)
Spark plug access cover (no.1)

3. Preparation before use

3.1. Positioning the generating set for operation
Choose a site that is clean, well ventilated and sheltered from bad weather.
Place the generating set on a flat, horizontal surface which is firm enough to prevent the set sinking down (under no circumstances
should the set tilt in any direction by more than 10°).
Store the additional supplies of oil and fuel within close proximity, whilst maintaining a certain distance for safety.
3.2. Earthing the generating set
Danger
To connect the set to the ground: Attach a 10 mm
driven 1 meter into the ground.

3.3. Checking the oil level

Before starting the generating set, always check the level of engine oil.
Supplement it with the recommended oil (see § Specifications) with the help of a funnel, up to the upper limit of
the gauge.
Important
Open the inspection cover (fig. A – no. 2).
Unscrew the oil filler plug (fig. B – no. 2).
Check the oil level.
If necessary supplement it.
Screw back the filler plug.
Wipe any excess oil with a clean cloth.
Close the inspection cover (fig. A – no. 2).
Never leave the battery close to a flame or fire.
Use only insulated tools.
Never use sulphuric acid or acid water to top up the electrolyte level.
/
S
T
A
R
T (no. 1)
/
S
T
A
R
T
The generating sets supply electrical current when in operation: risk of electrocution.
Connect the generating set to the ground at each use.
2
copper wire to the set's earth connection and to a galvanised steel earthing rod
Figure A
MAX / ECO Mode (no. 9)
Tank pressurisation pump (no.10)
Indicator lamps (no.11)
A. Operating light
B. Overload indicator
C. Oil safety indicator
Spark plug access cover (no.12)
Muffler (no.13)
Figure B
Oil filler and drain plug (no.2)
Maximum oil filling level
Figure C
Fuel filter (no. 4)
Figure D
Filter element (no.2)
Filter element cleaning
Figure E
Spark plug (no. 2)