Vending machine can point out some possible bad operations.
By clicking icon
E
N
be deleted by selecting icon
G
L
I
S
H
ALARM
--
"No comm"
A02 Waste level
A03 Water missing
A04
Cup Holder Empty
A05
Nozzles movement
error
A06 Sugar/stirrer dispenser
A07 Start of coffee unit in
closure
FAS International S.p.A. - Via Lago di Vico, 60 - 36015 SCHIO (VI) Italy - tel. +39 0445 502011 – fax +39 0445 502010 - e-mail:
13
This section is for qualified assistance staff only
Error history the eventual list present will be displayed, and all alarm conditions can
Reset error history
TIME-
OUT
FAILURE
(sec.)
Interrupted
communication
between display
board and power
board
5
max. waste level
reached
30
water supply
missing
120
Cups are missing
(still 3 deliveries
are available
during turret
change)
8
The nozzles
movement doesn't
reach the
dispensing / rest
position
4
The stirrers
dispensing unit
micro is defective
2
The unit control
micro does not
switch over when it
passes from the
open unit position
to the closed unit
position.

ALARMS

Check the connection to the boards
Check the condition of the connecting cables
Possible breakage of one of the two boards
*
drain waste bin
*
Check that the refusals level micro switches
correctly (see
Services
*
check correct opening of outer tap
*
check that there is no contraction in the inlet hose
*
check correct functioning of the inlet valve
*
load cups
*
Check that the cup presence micro (CPB) switches
correctly (see
Services
*
Check the correct operation of the column change
gear motor (MC)
*
Check the correct operation of the nozzles
movement gear motor (MTBC)
*
Check that the nozzles micro (CDB) switches
correctly (see
Services
*
Check that the stirrers dispenser micro (CDZP)
switches correctly (see
menu Services
*
Remove the g.e.p unit from the vending machine
and check, when empty, the correct rotation of the
coffee unit motor (Through the unit feed function). If
there are any inconveniences, Check that the coffee
unit is not clogged or broken. Otherwise, if there are
some inconveniences, you have to:
FAS 300 T - ISSUE 01
SOLUTION