EXTRAORDINARY MAINTENANCE, CLEANING OF COFFEE UNIT FILTERS

Switch off the machine by means of the main switch and pull out the power plug..
Pull off the coffee dispenser tube from the arms.
Pull off the water inlet tube by unscrewing the ring nut (ref.1).
Unscrew the knob and remove the unit from the support (ref.2).
Remove the hopper from its seat (ref.3).
Turn the lever to bring the infusion chamber to the position where the piston is extended as far as possible
(ref.4).
Remove the sealing rings, pull out the shafts from the pins, in order to extract the pressing element support
(ref.5).