Herunterladen Inhalt Inhalt Diese Seite drucken

Coffee Unit, Coffee Unit Presence Control - FAS 300 T Handbuch

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

FAS 300 T - ISSUE 01

COFFEE UNIT, COFFEE UNIT PRESENCE CONTROL

Infusion chamber is driven by a gear motor (MRGC) through a joint.
Microswitches MCRG - MCPG define the work positions of the unit during the coffee cycle, specifically:
• MCGR = OPEN UNIT POSITION
• MCPG = CLOSED UNIT POSITION (defines the motor stop in rest/dispensing position, infusion pump start,
opening of coffee solenoid valve.)
The coffee unit operation is managed by a microswitch (CPGC) which detects its presence in the support: if
the coffee unit is installed, it works properly otherwise the following functions are inhibited
Service function for the coffee unit feed
Service function for rinsing cycle for coffee unit
Service function for coffee grinding
Service function for ground coffee dosage
Inhibition of all the selections for espresso coffee + instant
FAS International S.p.A. - Via Lago di Vico, 60 - 36015 SCHIO (VI) Italy - tel. +39 0445 502011 – fax +39 0445 502010 - e-mail:
19
E
N
G
L
I
S
H
info@fas.it

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis