12
The operating pressure must range between 0.1 and
0.8 MPa. For the installation use only the parts
supplied; if you need to use other parts, use only new
parts (never used previously) that are suitable for
contact with water intended for human consumption
(in compliance with local regulations in force).
A tap must be installed between the water mains
outlet and the vending machine delivery tube so that
the passage of water may be closed off if necessary.
E
Connect the water delivery tube to the fitting (¾ gas)
N
that is already installed at the back of the vending
G
machine as indicated.
L
Screw it securely in place but without exerting
I
excessive force which could crack the fittings.
S
H

WARNINGS FOR THE INSTALLATION

The machine is sold without payment system. Therefore whatever default to the machine or damages to person
or things due to an incorrect installation, use or similar caused by the payment system will be only and
exclusively charged to those who have carried out the installation of the machine
After the installation procedure is completed, never store the safety switch key inside the
vending machine. The installer must take possession of the interlock key. The interlock
key must only be consigned to qualified assistance service personnel. Once the qualified
assistance service technician has completed the required operations as described in this
manual he must always remove the key from the vending machine, in order to prevent
the loader from using it.

INACTIVITY

If long periods of machine inactivity are expected, it is recommended to adopt adequate precautions to prevent
dangerous situations when the machine is re-started.
For long resting period, it is necessary:
To empty out the hydraulic circuit completely;
To empty out all the products from the canisters;
FAS International S.p.A. - Via Lago di Vico, 60 - 36015 SCHIO (VI) Italy - tel. +39 0445 502011 – fax +39 0445 502010 - e-mail:
INSTALLATION OF THE CABINET (WHEN
PROVIDED) :
The lock nuts are located in the fixing holes secured by
adhesive tape (see the instructions inside the cabinet).
How to insert the coffee grounds bag:
Use bags which are long enough to reach the bottom of
the vending machine.