The profile analysis will be horizontal.
- Vertical
The profile analysis will be vertical.
Isotherm type
Sets the isothermal analysis mode. There are five
modes: Dual Above, Dual Below, Above, Below and
Interval.
- Dual Above
Display the isothermal interval in a color and the
parts with the higher temperatures than the upper ‚
limit of the isothermal interval in a different color
- Dual Below
Display the isothermal interval in a color and the
parts with the lower temperatures than the lower
limit of the isothermal interval in a different color
- Above
Display the isothermal interval and the parts with
the lower temperature than the upper limit of the
isothermal interval in the same color.
- Below
Display the isothermal interval and the parts with
the lower temperature than the lower limit of the
isothermal interval in the same color
- Interval
Display the isothermal interval in one color and all
the other parts are displayed in the normal pseudo
color mode
Isotherm width
Sets the width of isothermal interval. The width can
be adjusted from 0.1 °C to the upper limit of the ma-
ximum temperature measurement range under this
condition.
Isotherm color
Sets the color of the isotherm interval. Transparent,
Green, Black and White are available.
Alert
Enable or disable the temperature alert. When the set-
ting is "On", the temperature reading of "Spot 10" will
B - 15
be displayed in red, meaning the alert status, if the set-
ting [Spot] / [Setup-analysis] is "Maximum", and the
measured temperature in "Spot 1" of "Manual adj" is
higher than the preset alert temperature. On the con-
trary, if "Spot 1", set as "Minimum" in [Spot] / [Setup-
analysis], has a temperature lower than the preset alert
temperature, the temperature reading will be displayed
in the alert mode.
Alert temp
Sets the temperature limit of "Alert".
Correct temp
Corrects the measured temperature value of the came-
ra to ensure the measurement accuracy under special
circumstances.

Spot analysis

1. Press the MENU/EN-
TER key.
2. Press the 3 Left or
Right4 arrow on the
omni selector to select
the [Analysis] menu.
3. Press Up
t
selector to select [Spot],
then press the Menu/
Enter key.
4. Setting the spot ana-
lysis.
- Press the UP
DOWN
the omni selector to
select a spot, then
press MENU/ ENTER
Key. One or more
crosshair will appear
on the screen.
- Spot 10 will automatically track the highest or
lowest spot on the screen.
Operating manual – Infrared camera
and DOWN
s
arrow on the omni
or
s
arrow on
t
G