10. trOuBles shOOtInG
Problem
Camera will not operate
Camera will not record
Battery pack consumed quickly
Battery pack will not charge
11. eMIssIvItY taBle
Material
Aluminum
Polished aluminum
Commercial alumi-
num foil
Electrolytic chrome-
plate alumina
Mild alumina
Strong alumina
Copper
Cuprous oxide
B - 23
cause
Power is not turned on
Insufficient battery voltage
Poor contact between camera and
battery terminals
Internal memory is full
Internal memory not
formatted correctly
Battery pack capacity reduced
because of disuse for one year or
more after being fully charged
Battery life exceeded
Poor contact between battery pack
and battery charger
Battery life exceeded
Temperature
Emissivity
(°C)
approximation
100
0,09
100
0,09
25 ~ 600
0,55
25 ~ 600
0,10 ~ 0,20
25 ~ 600
0,30 ~ 0,40
800 ~ 1100 0,16 ~ 0,13
Operating manual – Infrared camera
solution
Turn on the camera
Fully charge the battery
Wipe the terminals with a clean,
dry cloth
If required, download the images
to a computer and erase them
to make some space
Format the internal memory in
FAT16 format
Replace the battery pack
Replace the battery pack
• Clean the battery terminals
with clean cloth.
• Connect the power cord to the
battery charger and insert its
plug firmly into the power outlet.
Replace the battery pack
Material
Copper
Copper mirror
Strong copper oxide 25
Liquid copper
Brass
Brass mirror
Brass oxide
Chrome
Polished chrome
Gold
Gold mirror
Temperature
Emissivity
(°C)
approximation
100
0,05
0,078
1080 ~ 1280 0,16 ~ 0,13
28
0,03
200 ~ 600
0,61 ~ 0,59
40 ~ 1090
0,08 ~ 0,36
230 ~ 630
0,02
G