Herunterladen Diese Seite drucken

Shutting Down; Care And Service - Kärcher CWB 3 Originalbetriebsanleitung

3-bürsten-portalwaschanlage

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
10 litre refill canister
1
Overflow pipe
2
1. Screw the refill canister onto the overflow pipe.
2. Open the corresponding cleaning or care agent container.
3. Fill the reservoir and close it again.

Shutting down

Short-term shutdown
1. End the currently running washing program.
2. Leave the main switch set to "1" so that the optional frost pro-
tection device can remain activated.
Long-term shutdown
1. End the currently running washing program.
2. Drain all water lines if frost is to be expected during the shut-
down period.
3. Set the main switch to position "0".
4. Close the water supply line.
5. Close compressed air supply line.
6. Drain the cleaning and care agents.
Shutdown via the automatic frost protection device
ATTENTION
Damage to the system if the frost protection device is not
switched on
If frost is to be expected, take care to ensure that the main power
switch is switched on and no emergency stop buttons are actuat-
ed.
The following steps are performed automatically when the tem-
perature falls below the minimum temperature:
1. The currently running washing program is executed until fin-
ished.
2. After the washing program has finished, the hoses and nozzle
pipes of the portal are blown out with compressed air.
3. Starting of further washing programs is locked out.
Note
The system is automatically ready for operation after the danger
of frost has passed
Manually starting the automatic frost protection
ATTENTION
Damage to the system through temperatures below zero
Execute the frost protection process for the system.
Note
In systems with an automatic frost protection unit, the frost pro-
tection starts as soon as the preset temperature is reached.
36
(optional)
process
1. Select Service / Manual mode in the main menu.
2. Press the "Manual frost protection" button to start the frost pro-
tection process.
The frost protection process starts and the time remaining is
shown in the display.
Maintenance instructions
Regular maintenance according to the following maintenance
plan is fundamental for a safely operating system.
WARNING
Risk of injury from machine movements
Switch the system off before performing maintenance and servic-
ing work.
Secure the main switch with a padlock to prevent it from being
switched on again.
WARNING
Risk of injury from pressurised compressed air reservoirs
and lines after the system has been switched off
Depressurise the system before performing any work on the sys-
tem.
Check the pressure gauge at the maintenance unit to ensure that
the system is depressurised.
WARNING
Risk of injury from the high-pressure system after the sys-
tem has been switched off
Depressurise the high-pressure system before performing any
work on the system.
DANGER
Risk of injury from escaping compressed air, high-pressure
water at nozzle outlets and propelled dirt particles or similar
in the vicinity of the rotating brushes!
Dirt particles or loose objects can injure persons or animals when
propelled off the vehicle.
Compressed air or high-pressure water can remain pressurised
even when the system is switched off.
Keep the hall floor free of loose lying objects.
Exercise care when operating the compressed air system and
the high-pressure system.
Wear suitable safety goggles when performing maintenance
work.
English

Care and service

Werbung