Replacing the
Removing the EcoPS:
power board -
EcoPS
(4)
Inserting the EcoPS:
164
(1)
(1)
(3)
WARNING!
Observe the safety rules (see the begin-
ning of the "Safety" section)
Take the inverter out of the wall bra-
1
cket and open it (see "Opening and
closing the device" and necessary
„Replacing the Overvoltage PC board"
sections)
Disconnect all cables and plug connec-
2
(2)
tions (1-2) and thread them out
Undo the 11 4x9 TX20 screws (3)
3
Undo the six 4x9 TX20 screws (4) on
4
the solar modules
Remove the EcoPS
5
Remove any old PCM paste residues
6
from the heat sink using a clean cloth
NOTE!
Ensure you remove all PCM paste resi-
dues
NOTE!
If you are returning the EcoPS, the solar
modules must also be cleaned with a
clean cloth.
- Take the PCM film from the small parts kit
- Position it on the solar modules and smoo-
th it out
- Ensure that all the protective film is remo-
ved!