NOTE!
To ensure a sufficient EMC connection
is established, all EMC springs must be
present
Make sure that the eleven EMC
1
springs are seated correctly - slight
notches hold the EMC springs in place
(The overvoltage PC board may be located
in the marked area (5))
Position the power stage set cover and
2
fit it using six 5x16 TX20 screws (4)
[3 Nm]
(4)
Fronius Eco: fit the EMC bracket
NOTE!
(4)
If the screws no longer fit tightly, they
must be replaced with new 5x25 TX25
screws [42,0401,4231]
(4)
NOTE!
To avoid damaging the base shell, do
not angle the inverter by more than 11°.
(3)
Attach the inverter at the top and allow
3
it to engage in the mounting bracket
Fit the two 5x25 TX25 (3) screws to
4
hold the inverter securely in the moun-
ting bracket
[2.5 Nm]
If applicable, connect all plug connec-
5
tions