Inserting the SymoPS DC:
162
Undo the four 4x9 TX20 screws (3) on
4
the solar modules
Insert the screwdriver into the "Remo-
5
ve Print" hole (4) and detach the Sym-
oPS DC from the heat sink in the
direction of the arrow
Remove the SymoPS DC
6
Remove any old PCM paste residues
7
from the heat sink using a clean cloth
NOTE!
Ensure you remove all PCM paste resi-
dues
NOTE!
If you are returning the SymoPS DC, the
solar modules must also be cleaned
with a clean cloth.
- Take the PCM film from the small parts kit
- Position it on the solar modules and smoo-
th it out
- Ensure that all the protective film is remo-
ved!
NOTE!
Do not press on the marked area ->
this will damage the PCM material
Detach the blister packs from the new
1
SymoPS DC at the tabs and place
them on the faulty SymoPS DC

Quicklinks ausblenden: