Technical data
Fluid pressure
The fluid pressure may be restricted
by the fluid temperature, the material
the flow sensor is made of, the
material the S020 fitting used is made
of and the DN of the fitting used.
• 8045 with flow sensor
• PN10
in PVDF
• 8045 with flow sensor in
• PN16
stainless steel
A
P (bar)
10
9
8
7
PVC + PP
6
5
4
3
PVC (PN10)
2
1
0
0
+20
+40
A: range of use
Fig. 2:
Fluid pressure /temperature dependency for a 8045 with
PVDF flow sensor and a fitting S020 in metal, PVC, PVDF
or PP
Type 8045
PVDF (PN10) /
Metal
PP (PN10)
T (°C)
+60
+80
P (bar)
16
15
Metal
14
(PN16)
13
12
PVDF
11
10
9
8
PVC + PP
7
6
5
4
PVC (PN10)
3
2
1
0
-20
0
+20 +40 +60 +80 +100 +120
Except DN100 for measuring devices with a clamp connection
1)
A: range of use
Fig. 3:
Fluid pressure /temperature dependency for a 8045 with
stainless steel flow sensor and a fitting S020 in metal,
PVC, PVDF or PP
English
A
1)
DN100 for measuring
devices with a clamp con-
nection (PN10)
PVDF (PN10)
PP (PN10)
T (°C)
9