CANBus
QuantumX / SomatXR and CCP / XCP-on-CAN
Processing can be stopped and started again at any time
using this control item. The "CANECU" control item uses
these parameters to start and stop:
Connector Number of the CAN bus connections
(„1...4", „0": all)
Index
Index of the ECU, currently always "1".
Mode
Choose the functionality "1": Start / Stop
Value
Choose between Start ("1") and Stop ("0")
The "catman" PC software maps control in a correspon­
ding dialog based on the control item.
7.5

General Workflow

Start CANape from Vector Informatik and read in the
*.a2l file. Now create a measurement configuration with
all the relevant signals you need acquire by MX471B.
Now convert the measurement configuration to a *.dbc
file.
Start MX Assistant and read in *.dbc and *.skb files (if
applicable) and download it to the device. Immediately
CCP or XCP-on-CAN communication will be started bet­
ween ECU and MX471B. This service can also be
activated and deactivated by a script running in catman
(under work).