Interval
Where?
All 100 and
500
operating hours
WARNING!
Unadequate lubricants may reduce the clamping force by more than 50%
INFORMATION
The spindle bearings are permanently greased. Greasing during the maintenance intervals is
not necessary. Further greasing of the spindle bearings is only necessary in case of de- and
remounting of the spindle bearing.
4.3

Repairs

Request for a service technician of the company Optimum Maschinen Germany GmbH for all
repairs.
If the repairs are carried out by qualified technical staff, they must follow the indications given in
these operating instructions.
The company Optimum Maschinen Germany GmbH does not take responsibility nor does it
guarantee for damages and failures resulting of non-observance of this operating manual.
For repairs only use
only use faultless and suitable tools,
original parts or parts from series expressly authorized by Optimum Maschinen Germany
GmbH.
GB
TU2506 | TU2506V | TU2807 | TU2807V
Page 148
What?
How?
Approximately every 100 operation hours a cleaning of the
jaw guidance is to be performed, depending on the operating
conditions, a complete cleaning is to be performed about
every 500 operating hours.
Leave the jaw chuck on the machine.
Clean and
Clean the jaws (do not use compressed air) and then
regrease
unscrew them. Thoroughly clean with kerosene or with
benzine.
Relubricate with Molykote TP 42.
Make sure that the jaws are in the correct order.
Original operating instructions
Maintenance
Version 1.0.1
2014-05-16