7
Commissioning
Parameter setting with the XT EMZ9371BC keypad

Vector control

7.4.2
Vector control
The following instructions apply to controllers equipped with a standard−I/O function
module and a three−phase AC motor which has been selected according to a power−based
assignment.
Switch−on sequence
1.
Plug in the keypad
2.
Ensure that controller inhibit is active after mains
connection
3.
Switch on the mains
4.
After approx. 3 s the keypad is in the operating level
and displays the output frequency (C0050) and the
device utilisation (C0056)
5.
For quick commissioning you select the "Quick
start" menu
Change the menu level with V
A
B
Change to the "Quick start" menu and there to the
"VectorCtrl qu" submenu with z z Z z
Change to the code level with Z to parameterise
C
your drive
6.
Adapt the voltage/current range for the analog
setpoint selection (C0034)
Lenze setting: 0, (0 ... 5 V/0 ... 10 V/0 ... 20 mA)
7.
If required, adapt the fixed setpoints JOG.
A
JOG 1 (C0037)
Lenze setting: 20 Hz
B
JOG 2 (C0038)
Lenze setting: 30 Hz
C
JOG 3 (C0039)
Lenze setting: 40 Hz
8.
Set the minimum output frequency (C0010)
Lenze setting: 0.00 Hz
9.
Set the maximum output frequency (C0011)
Lenze setting: 50.00 Hz
10.
Set the acceleration time T
Lenze setting: 5.00 s
11.
Set the deceleration time T
Lenze setting: 5.00 s
186
z
Y Z
y
C0011
C0010
(C0012)
ir
f [ H z ]
C 0 0 1 1
f 2
f 1
(C0013)
if
0
l
Comment
}
X3
Terminal X3/28 = LOW
20
28
misc001
ON
misc002
d
c
b
B
A
0050
00
0.00 Hz
0 %
9371BC004
The submenu "VectorCtrl qu" contains
the codes which you require for
d
c
b
B
A
commissioning a standard application.
p
SHPRG
Menu
4
3
Code
Para
The digital inputs are configured in
Quick start
Lenze setting:
V e c t o r C t r l q u
X3/E1, X3/E2: activation of fixed
9371BC006
setpoints (JOG)
X3/E3: activation of DC injection brake
d
c
b
B
A
SHPRG
p
Menu
0034
00
Code
Para
(DCB)
0
A I N 1 r a n g e
X3/E4: CW rotation/CCW rotation
9371BC008
Set the DIP switch on the standard I/O
to the same range (see Mounting
Instructions for the standard I/O)
Activation:
X3/E1 = HIGH, X3/E2 = LOW
Activation:
X3/E1 = LOW, X3/E2 = HIGH
Activation:
X3/E1 = HIGH, X3/E2 = HIGH
[f]
0 %
100 %
T
+ t
ir
t
= desired acceleration time
ir
T
+ t
if
t
t i r
t i f
T i r
T i f
t
= desired deceleration time
if
C0011
@
ir
f 2 * f 1
C0011
@
if
f 2 * f 1
EDK82EV903 DE/EN/FR 4.0

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis