4
Mechanical installation
Standard devices in the power range 15 ... 30 kW
Mounting in "cold plate" technique
)
Note!
Before assembling the controller, please read the documentation for the
components connected on the supply side (mains choke, filter).
8200 vector
E82CV153K4B
E82CV223K4B
1)
If the function module is attached: observe mounting clearance and cable bending radius. The terminals of function
modules in PT design protrude above the housing by 8 mm.
Mounting
Apply heat conducting paste before screwing together the cooler and cooling plate of the
drive controller so that the heat transfer resistance is as low as possible.
1. Clean the contact surface of cooler and cooling plate with spirit.
2. Apply a thin coat of heat conducting paste with a filling knife or brush.
– The heat conducting paste in the accessory kit is sufficient for an area of approx.
1000 cm
3. Mount the drive controller on the cooler.
130
a
a1
b
234
250
381
2
.
l
Dimensions [mm]
b1
c
c1
350
110
220
8200vec301
1)
d
e
g
367
171
6.5
EDK82EV903 DE/EN/FR 4.0