Vector control

The following instructions apply to controllers equipped with a standard−I/O function
module and a three−phase AC motor which has been selected according to a power−based
assignment.
Switch−on sequence
1.
Connect keypad
2.
Ensure that controller inhibit is active after mains
connection
3.
Switch on the mains
4.
The keypad is in "Disp" mode after approx. 2 s and
indicates the output frequency (C0050)
5.
6.
Go to the ALL menu
Change to the f mode to configure the basic
7.
settings for your drive
8.
Adapt the terminal configuration to the wiring
(C0007)
Lenze setting: −0−, i. e.
E1: JOG1/3 fixed setpointselection
E2: JOG2/3
E3: DCB DC brake
E4: CW/CCW rotation
9.
Set the minimum output frequency (C0010)
Lenze setting: 0.00 Hz
10.
Set the maximum output frequency (C0011)
Lenze setting: 50.00 Hz
11.
Set the acceleration time T
Lenze setting: 5.00 s
12.
Set the deceleration time T
Lenze setting: 5.00 s
13.
Activate the control mode "vector control" (C0014 =
4)
Lenze setting: Linear V/f characteristic control
(C0014 = 2)
14.
Adapt the voltage/current range for the analog
setpoint selection (C0034)
Lenze setting: −0−, (0 ... 5 V/0 ... 10 V/0 ... 20 mA)
EDK82MV371 DE/EN/FR 7.0
(C0012)
ir
(C0013)
if
l
Commissioning
Vector control
Comment
Terminal X3/28 = LOW
The USEr menu is active
Blinking on the display: 0050
d
c
b
B
p
SHPRG
Menu
0014
Code
Para
V e c t o r - C t r l
Set the DIP switch on the standard I/O
to the same range (see Mounting
Instructions for the standard I/O)
7
A
00
4
9371BC008
113