4.2.3
Mounting in "cold plate" technique
For this mounting variant you require the controller type E82CV...
The following points are important for safe and reliable operation of the controller:
Good thermal connection to the cooler
ƒ
– The contact surface between the collective cooler and the controller must be at
least as large as the cooling plate of the controller.
– Plane contact surface, max. deviation 0.05 mm.
– When attaching the collective cooler to the controller, make sure to use all
specified screw connections.
Observe the thermal resistance R
ƒ
controller operation under rated conditions.
8200 vector
Ñ Ñ Ñ Ñ Ñ Ñ
E82CV153K4B
Ñ Ñ Ñ Ñ Ñ Ñ
Ñ Ñ Ñ Ñ Ñ Ñ
E82CV223K4B
Ambient conditions
The rated data and the derating factors at increased temperature also apply to the
ƒ
ambient temperature of the drive controllers.
Temperature at the cooling plate of the drive controller: max. 75 °C.
ƒ
EDK82EV903 DE/EN/FR 4.0
Standard devices in the power range 15 ... 30 kW
th
Power to be dissipated by the heatsink
P
[W]
v
Ñ Ñ Ñ Ñ Ñ Ñ Ñ Ñ Ñ Ñ Ñ Ñ
287
Ñ Ñ Ñ Ñ Ñ Ñ Ñ Ñ Ñ Ñ Ñ Ñ
Ñ Ñ Ñ Ñ Ñ Ñ Ñ Ñ Ñ Ñ Ñ Ñ
427
l
Mechanical installation
Mounting in "cold plate" technique
given in the table. The values are valid for
Cooling path of heatsink − ambience
Ñ Ñ Ñ Ñ Ñ Ñ Ñ Ñ Ñ Ñ Ñ Ñ Ñ
Ñ Ñ Ñ Ñ Ñ Ñ Ñ Ñ Ñ Ñ Ñ Ñ Ñ
Ñ Ñ Ñ Ñ Ñ Ñ Ñ Ñ Ñ Ñ Ñ Ñ Ñ
4
R
[K/W]
th
£ 0.085
£ 0.057