4
Mechanical installation
Standard devices with a power of 55 kW
Modification of the fan module for push−through technique
4.4.3
Modification of the fan module for push−through technique
For thermally separated mounting the fan module has to be rotated by 180° so that the
controller fits into the mounting cutout.
Removing the fan module
Fig. 4−1
1. Remove both screws.
The screws connect the fans to the supply voltage.
2. Remove the 4 screws for fixing the fan module on each side.
3. Pull back the fan module and carefully remove it to the top.
Make sure that the threaded sleeves do not touch the housing edge. They may break
off.
Modifying the threaded sleeves on the fan module
Fig. 4−2
1. Remove the threaded sleeves.
2. Screw−in the threaded sleeves on the opposite side and fasten them.
138
Removing the fan module from the controller
Modifying the threaded sleeves for the voltage supply of the fans
l
9300vec170
9300vec171
EDK82EV903 DE/EN/FR 4.0