Checking the thermocouple
The thermocouple monitors the burning process and ensures that the gas supply
to the burner is interrupted when the flame goes out. Each burner is monitored by
its own thermocouple.
If the contact connection is faulty, malfunctions may occur.
A loose thermocouple contact must be tightened.
Remove the worktop.
Carefully tighten the connection of
the thermocouple that is not working
(spanner size 8).
7.6
Drying the burner
Water can collect in the burner during heavy rainfall.
Moisture in the burner can severely impair its function and performance.
Make sure that the appliance is not operated with wet burners.
Remove the removable parts.
"6.4 Cleaning the removable parts" (page 71).
Dry the burner and appliance.
Dry the removable parts.