11 Alarm forwarding
and alarm stop
Alarm forwarding takes place in two
directions with the following forward-
ing times:
Alarm forwarding within a radio
group or a shared radio group
= up to approx. 20 seconds.
Alarm forwarding from the radio
group to the shared radio group
= up to approx. 60 seconds.
There is no alarm forwarding from the
shared radio group to the individual ra-
dio groups.
Repeater function
Through the repeater function, radio sig-
nals are forwarded from one signalling
device through available devices to un-
reachable devices.
If you need specific and/or com-
plex connection functions for the
alarm forwarding, please con-
tact the manufacturer
(see chapter 15 "Accesso-
ries, spare parts and prod-
uct support" on page 79).
70
User Manual: XSD200 - Smoke Alarm Device with Radio Link
11.1 Alarm stop
You can mute an alarm by pressing the
test/stop button for 3-4 seconds.
If there is still a risk of fire after
an alarm stop, the switched-off
devices ring again after 10
minutes.
Alarm stop if the alarm forwarding
Alarm stop if the alarm forwarding
has not yet occurred
has not yet occurred
If the alarm forwarding has not yet taken
place, you can stop the alarm directly on
the alarm-triggering device:
f Press the testing/stop button on the
device triggering the alarm.
5 Alarm is stopped and will not be
forwarded.
Alarm stop if the alarm forwarding
Alarm stop if the alarm forwarding
has already occurred
has already occurred
If the alarm forwarding has already tak-
en place in a radio group, and you can
identify the alarm-triggering device, pro-
ceed as follows:
f Press the testing/stop button on the
device triggering the alarm.