5. Messages from the CIM 25X
The CIM 25X will send messages in case of faults or
other special conditions in the module itself. These
messages do not depend on the Grundfos product.
They can be enabled/disabled with the command
SMSALARM <ON | OFF>. If SMSALARM is set to
ON, they will be sent to all numbers in the phone
number list.
Note: No message will be sent if the phone number
list is empty (for instance, if the module has not been
initialised).
The message is triggered by an event. If the
CIM 25X is switched off and on (the battery must be
removed), it will send the message again if the cause
of the message still exists.
5.1 No connection to product
If the communication between the CIM 25X and the
Grundfos product is interrupted for more than one
minute, the CIM 25X will send this message to all
numbers in the phone number list.
[Installation name]
GSM module error:
No connection to product
Note: If the cause of the interruption is the fact that
the power supply to the product was interrupted, the
CIM 25X will send this message instead:
No mains supply, using battery.
See below.
5.2 No mains supply, using battery
If the CIM 25X detects that it is being supplied from
the battery, it will send this message to all numbers
in the phone number list:
[Installation name]
GSM module error:
No mains supply, using battery
This fault type will probably disappear by itself, as
the message is typically triggered by a short power
cut. In case of this special fault (but not the other
ones), the CIM 25X will send a message, telling that
the fault has disappeared:
[Installation name]
GSM module:
Mains supply returned
If the battery is worn out or the CIM 25X has no
battery, the CIM 25X will not detect if the power
supply to the Grundfos product has been interrupted,
as it will loose power supply itself. It can therefore
not send a message. To inform the user that there
has been a power cut, the CIM 25X will always send
a message when the power supply has returned:
[Installation name]
GSM module:
Power on occurred
5.3 Change GSM module battery
If the CIM 25X detects that the battery is worn out
and must be replaced, it will send this message to all
numbers in the phone number list:
[Installation name]
GSM module error:
Change GSM module battery
Note: The CIM 25X GSM module battery is optional.
5.4 GSM module battery low
If the CIM 25X detects that the battery level is low, it
will send this message to all numbers in the phone
number list:
[Installation name]
GSM module error:
GSM module battery low
Note: The CIM 25X GSM module battery is optional.