Herunterladen Inhalt Inhalt Diese Seite drucken

BestWater Jungbrunnen 66-10 Gebrauchsanleitung Seite 92

Vorschau ausblenden Andere Handbücher für Jungbrunnen 66-10:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Maintenance of the BestWater system
EN
the power cord from the
Now you should disconnect all tubing
connections to and from the device.
Disconnect the hoses
In order to loosen the hose connections
press the hoses into the quick coupling,
JUNGBRUNNEN
hold on to the coupling ring and pull out
the hose again.
66-10/11
To change the fi lter units, please open
the right side of the system. For this
purpose, you need the Torx wrench T15.
Loosen the 4 casing screws. The fi rst
screw is located at the bottom left on the
side part of the casing.
You will fi nd another three screws at the
left rear side of the casing. When open-
ing the casing, please use no force.
Open maintenance cover with Torx angled screwdriver
®
92
device.
Bitte 5 cm Abstand
zur Rückwand halten!
Schlauchverbindungen dürfen nicht knicken!
Abwasser
Tank
Hahn
Leitungswasser
Torx angled screwdriver
After you have loosened the screws you
can pull the right casing cover back-
wards. The cover is unhooked upwards.
Slide the maintenance cover to the right & unhook it upwards.
®
Next, remove all prefi lters. For this
purpose, use the prefi lter housing key
and begin with the middle prefi lter
(activated charcoal).
The used fi lters can be disposed of in the
household waste/residual waste or recy-
cled.
Remove the prefilter with the prefilter housing key
Sediment prefilter 1µ
Active carbon prefilter
After removing the old pre-fi lter in-
serts, clean the seals. The seals should
be slightly greasy after cleaning. If this
Sediment prefilter 5µ

Werbung

Inhaltsverzeichnis
loading

Verwandte Produkte für BestWater Jungbrunnen 66-10

Diese Anleitung auch für:

Jungbrunnen 66-11

Inhaltsverzeichnis