If an X-node is connected to a USB cable for the charging process,
the position alarms will be suppressed.
Battery runtime and charging time
The default battery runtime when fully charged and in continuous
operation is approx. 12 months.
The following table lists battery runtimes for X-nodes in continuous
operation with various sensors, which are calculated on the basis of
measurements. The factory settings have not been changed for any
measurement, which means the status LED flashes every 60 seconds
and the LoRa transmission interval is 300 s. The X-node uses
firmware 2.0.7 and the LoRa reception is of average quality. All
measurements have been carried out at 20 °C, 50 % relative humidity
and in atmospheric conditions.
X-node with sensor Measurement inter-
val (1/s)
NH
(AL)
1
3
O
1
2
CO
60
2
Depending on configuration, installation location, sensor used and
external circumstances, the runtime may exceed or fall below what is
expected. In particular, the distance to the LoRa gateway is important
as, depending on error rate, the emissions with stronger transmission
power and longer duration are also repeated when the distance is
longer. The X-node itself does not influence this behaviour as these
parameters are set by the controlling LoRa network server in the
LoRaWAN network. The energy consumed by the sensors used also
Technical manual
|
Dräger X-node
varies. Other external circumstances that influence the battery
runtime include the concentration of measured gas in the air and the
number of alarms triggered.
Favourable configurable factors for an increased battery runtime
include:
– Long display interval
– Setting the discreet mode (no LED signals)
– Long LoRa transmission interval
– "Flashing" display pattern instead of "pulsing"
– Infrequent Bluetooth connections
Overview of all status LED displays
Status visualisation Charging
The X-node flashes
Projected battery
in accordance with
runtime
the display interval.
The colour of the sta-
Approx. 24 months
tus LED changes
approx. 10 months
according to the mea-
sured value and
Approx. 18 months
alarm thresholds A1
and A2.
Operation and controls
Other
If the X-node is tilted
by more than 30°
while charging, the
status LED will pro-
vide information
about the charging
progress.
|
en