Herunterladen Inhalt Inhalt Diese Seite drucken

HBM C10 Montageanleitung Seite 20

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Mechanical installation
Force application is implemented via the convex load button on the top of the
force transducer. We recommend using our thrust pieces, to ensure ideal force
application. These thrust pieces, which are placed on the convex load button,
have a suitable surface quality.
Fig. 6.2
Correct thrust piece placement, substructure
If you want to do without a thrust piece, please note that the structural
component that applies the force to the convex load application part must be
ground, and have a hardness of at least 40 HRC.
The substructure must be capable of absorbing the force to be measured.
Remember that the stiffness of the overall system depends on the stiffness of
the force application part and the substructure. Please also note that the
substructure must ensure that force always has to be applied to the transducer
vertically, i.e. there must be no inclination, even under full load.
There is a centering aid and four threads underneath the adapter, by means of
which the C10 can also be mounted upside down or vertically.
Nominal (rated) force
2.5 kN ... 50 kN
100 kN ... 250 kN
18
500 kN
1 MN
A04036_01_YI0_03 HBM: public
Thread
M6
M8
M12
M16
C10