≤ 2 cm (e.g. paths that can be travelled on,
patios):
Route the perimeter wire without
clearance to the obstacle.
Take care not to damage the
perimeter wire when tending to the
lawn edge. If necessary, install the
perimeter wire at a slight distance
(2-3 cm) from the lawn edge.
> 2 cm:
Route the perimeter wire at distance C
(27 cm).
If necessary, set the cutting height
so that the mowing deck of the
robotic mower does not hit the
obstacles.
If the lowest cutting height is set,
the robotic mower can
consequently only clear lower
stepped areas than specified.

12.6 Confined areas

If a confined area is installed in the
mowing area then offset drive home
(corridor) must be deactivated.
(
11.14)
132
The robotic mower travels automatically in
all confined areas, provided the minimum
wire clearance is maintained. Narrower
areas of the mowing area must be blocked
off through appropriate routing of the
perimeter wire.
If two mowing areas are linked via a
narrow passage that can be travelled on, a
corridor can be installed. (
Minimum wire clearance: 54 cm
This corresponds to 2 iRuler lengths or the
machine width.
This results in the following space
requirements in confined areas:
– between high obstacles (> 2 cm –
e.g. walls, hedges):
108 cm
– obstacles which can be travelled on (≤
2 cm – e.g. paths, patios):
54 cm

12.7 No-go areas

No-go areas have to be installed
– around obstacles that the robotic
mower must not touch
– around obstacles that are not
sufficiently sturdy
– around obstacles that are too low.
Minimum height: 10 cm
VIKING recommends
● blocking off obstacles by means of no-
go areas or removing them,
12.9)
● checking no-go areas after initial
installation or after changes to the wire
installation using the "Test edge"
command. (
Minimum clearance A from the no-go
area to the edge loop: 54 cm
This clearance corresponds to 2 iRuler
lengths.
11.14)