Then press the OK button on the
control panel.
If the battery is discharged, a
plug symbol appears instead
of the battery symbol at the
top right corner of the display after
docking and the battery is charged
while the perimeter wire is being
routed. (
15.8)

9.6 Routing the perimeter wire

Please read and observe the entire
"Perimeter wire" section before
performing wire routing. (
In particular, plan the routing,
observe the wire clearances and
install no-go areas, reserve wire,
linking sections, secondary
areas and corridors during wire
routing.
0478 131 9931 B - EN
Fasten the perimeter wire (1) to the ground
12.)
on the left A or right B as appropriate,
next to the floor plate, directly next to a
wire outlet, using a fixing pin (2).
Provide a free wire end (1) with a length of
approx. 1 m.
Internal docking station:
Route the perimeter wire (2) in front of and
behind the docking station (1) for 0.6 m in
a straight line and at right angles to the
floor plate. Then follow the edge of the
mowing area with the perimeter wire.
If the staggered drive home
(corridor) is used, the perimeter
wire must be routed at least 1.5 m
in front of and behind the docking
station in a straight line and at right
angles to the floor plate. (
11.14)