Herunterladen Inhalt Inhalt Diese Seite drucken

Viking iMow MI 632 Gebrauchsanleitung Seite 155

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Message:
0505 – Mowing motor fault
Mowing blade blocked
Possible cause:
– Dirt between carrier plate and mowing
deck housing
– Mowing motor cannot be switched on
– Mowing motor overloaded
Remedy:
– Clean mowing blade and mowing deck
(
16.2)
Clean carrier plate (
16.6)
– Set higher cutting height (
– Level out any uneven areas (holes,
depressions) in the mowing area
Message:
0701 – Battery fault
Outside temperature range
Possible cause:
– Temperature in battery too low or too
high
Remedy:
– Allow the robotic mower to warm up or
cool down – observe permissible
temperature range of battery (
Message:
0703 – Battery discharged
see message 0100
Message:
0704 – Battery discharged
see message 0100
0478 131 9931 B - EN
Message:
1000 – Rollover
Allowed inclination exceeded
Possible cause:
– Tilt sensor has detected a rollover
Remedy:
– Place the robotic mower on its wheels,
check for damage and confirm the
message with OK
Message:
1010 – iMow raised
9.3)
Press OK to release
Possible cause:
– Robotic mower has been lifted by the
hood
Remedy:
– Check movement of the hood and
confirm the message with OK
Message:
1020 – STOP button pressed
Press OK to release
Possible cause:
6.4)
– STOP button has been pressed
Remedy:
– Confirm message with OK
Message:
1030 – Hood fault
Check hood
Then press OK
Possible cause:
– No hood detected
Remedy:
– Check hood (movement, firm seating)
and confirm the message with OK
Message:
1100 – Control panel
Control panel removed during travelling
Possible cause:
– Control panel has been removed during
automatic operation
Remedy:
– Confirm the message with OK –
automatic operation resumes once the
control panel has been inserted
Message:
1120 – Hood blocked
Check hood
Then press OK
Possible cause:
– Permanent collision detected
Remedy:
– Free the robotic mower, remove the
obstacle or change routing of perimeter
wire if necessary – then confirm the
message with OK
– Check movement of the hood and
confirm the message with OK
Message:
1125 – Remove obstacle
Check wire routing
Possible cause:
– Perimeter wire routed inaccurately
Remedy:
– Check the routing of the perimeter wire;
check the clearances with the iRuler
(
12.5)
153

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis

Fehlerbehebung

loading

Diese Anleitung auch für:

Imow mi 632 cImow mi 632 pImow mi 632 pc