Herunterladen Inhalt Inhalt Diese Seite drucken

ECOLAB DryExxEco Advanced-ETH Betriebsanleitung Seite 170

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

4
Activation time (set and actual). Use the normal cycle
and pause times.
5
Cycle time
6
Pause time (set)
7
Explanations on the settings:
Waiting time to activation (set and actual)
n
Time after which the booster function becomes active.
n
The time runs when the enabling signal is not active.
Activation time (set and actual)
Time for which the booster function is active.
n
n
The normal cycle and pause times are then used.
Current "activation" status
n
When the "After" waiting time elapses, the signal becomes active.
Cycle and pause time (set)
n
These times are used, if:
– the "After" waiting time has elapsed.
– The enabling signal is active.
– The "For" active time has not yet elapsed.
This function is only switched on when values have been entered in both
"After" and "For" times.
This function is switched off when "Zero" has been entered for the values for
the "After" and "For" times.
Layout of the software display
Overview: Circuit Parameters > Circuit parameters - Boost times
8
Current "activation" status When the "After" waiting
time elapses, the signal becomes active
9
Sequential valve number on the system
10 Circuit number