Trouble shooting Magnetic sensor and magnetic tape

Typical errors that occur during operation:
The value shown on the display does not correspond to the actual value because the
parameter setting for the counting resolution is set improperly.
Reading head is incorrectly connected. Check the connection.
The gap tolerance between measuring head and measuring jib was not maintained across
the entire measurement range.
Cable interruption / cut by sharp edges / cable squeezed.
Moisture has penetrated extension cable plugs.
Travel speed is too high; it should not exceed 0.5 meters per second.
The replacement measuring jib is not from the same manufacturer as the original
measuring jib. The actual counting resolution of the measuring jib does not correspond to
the set value.
7.2.8

Ball scales

Ball scales pin assignment
PIN No.
Ball scales signal
Ball scales are already protected against dust and dirt in their design. Nevertheless, protection
against external mechanical influences should be provided. Avoid strong temperature
fluctuations, shock or vibration.
Version 1.0.6 - 2022-05-17
0.2
1
2
3
4
not in
+12V
E+
E-
use
Translation of original instruction
Plastic support
5
6
7
8
not in
not in
S
0V
use
use
0.2
Plastic support
9
Housing
not in
Shielding
use
DPA32 CSS
EN
197

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis