4
Configuration over the CANopen interface (continued)
4.7

Restore factory settings

To reset the BMD CANopen sensor to its factor settings,
the signature load must be written to the object 0x1011:1.
The loaded factory settings are at first volatile. Only
resaving are the factory settings permanently applied.
ID
0x600 + node ID
0x580 + node ID
Tab. 4-12: Resetting all parameters
www.balluff.com
0x1011:1 Load all parameters
Data
23 11 10 01 6C 6F 61 64
60 11 10 01 00 00 00 00
Comment
Download 0x1011:1 (0x6C6F6164)
Confirmation of write command