Factory setting

Reset the sensor to its factory default setting using the
system command (0x0002) Restore Factory Settings
(0x82). By default, the additional functions Counter func-
tions are disabled.
For a listing of all parameters that can be set via IO-Link,
see section IO-Link interface: Parameters, commands and
events on page 19.
Parameter
Teach-in Channel
Switch Point Logic
Switch point mode
Set Point 1
Set Point 2
Pin Function Selection PIN 4
Pin Function Selection PIN 2
Physical Input Debounce PIN 2
Output Type PIN 4
Output Type PIN 2
Output Function PIN 4
Output Function PIN 2
Device Access
Application Specific Tag
Function Tag
Location Tag
Switch Counter Mode
Switch Counter Limit
Switch Counter Debounce
Switch Counter Startup Delay
Switch Counter Upper Limit High 0x0000
Switch Counter Upper Limit Low
Switch Counter Lower Limit High 0x0000
Switch Counter Lower Limit Low
Tab. 9-1:
Factory setting
www.balluff.com
Factory setting
Description
0x00
Manufacturer / vendor specific default (BDC 1)
0x00
High active
0x01
Single Point Mode
Variable
Manufacturer calibrated rated switching distance
0000
0x00
Sensor Output
0x01
Teach-in Input
0x12C (300)
300 ms debounce time
0x03
Push-Pull
0x03
Push-pull (not used, PIN 2 is by default an input.)
0x00
N.O.
0x00
N.O. (not used, PIN 2 is by default an input.)
0
All functions enabled
„***"
„***"
„***"
0x00
OFF
0x0000
OFF
0x0000
OFF
0x0000
OFF
OFF
0x0000
OFF
OFF
0x0000
OFF