Switching frequency
1)
A = U
-connections reverse polarity protected
B
B = inputs and output reverse-polarity protected
D = outputs overcurrent and short-circuit protected
2)
Signal transit time with resistive load
3)
Switching frequency and response time via IO-Link adjustable between 1 ... 50 Hz / 0.02 ... 0.5 s
4)
Depending on type
5)
With light / dark ratio 1:1
8)
Valid for Q\ on Pin2, if configured via software
Mechanical data
Enclosure rating
Ambient temperature, operation
11.2

Dimensional drawings

8027506/2022-02-28 | SICK
Subject to change without notice
4)
16
(0.63)
3
1
2
4
5
9
(0.35)
5.6
(0.22)
67
8
8
(0.32)
Ø 6.2
(0.24)
Figure 19: Dimensional drawing 1, cable
Preferred direction of the target
1
object
Center of optical axis, sender
2
Center of optical axis, receiver
3
M3 threaded mounting hole
4
Connection
5
Green LED: Supply voltage active
6
Yellow LED: status of received light
7
beam
Press-turn element / Potentiome‐
8
ter / Teach-Button: adjusting the
sensing range
2 Hz / 10 Hz
5)3)
WTB4FP-xxxxx1
IP66, IP67
-40 °C ... +60 °C
12.1
16
(0.48)
3
1
2
4
5
9
Ø 6.8
(0.27)
5.6
(0.22)
8
8
(0.32)
Figure 20: Dimensional drawing 2, male
connector
O P E R A T I N G I N S T R U C T I O N S | W4F MultiPulse
11
TECHNICAL DATA
2 Hz / 10 Hz
5)3)
WTB4FP-xxxxx2
IP66, IP67
-40 °C ... +60 °C
12.1
(0.63)
(0.48)
(0.35)
M8
(0.31)
67
Ø 6.2
(0.24)
en