6 Commissioning
The following position numbers refer to:
 Fig. 9 Mounting the cable assembly – iCAT mini for ABIROB
page EN-19
4 Mount the bellows (13) with the opening for compressed air hose (wire brake) (6) on the
release flange of the iCAT mini (7). Note the alignment of the bellows.
The compressed air hose (6) must be guided through the opening (2) of the bellows.
The opening (1) in the bellows should be aligned with the mounting hole (4).
5 Screw the wire brake (5) into the provided mounting hole (4) on the cable assembly until
it stops.
6 Connect the compressed air hose wire brake (6) to the wire brake (5).
NOTICE
• The wire feeder must be attached to the wire feeder mount.
 5 Fix the wire feeder (1) to the wire feeder mount (3). on page EN-17
EN - 20
iCAT mini
®
G with wire brake on
BAL.0361.0 • 2021-02-25