15.4.4 Fitting the saw blade (fig. 26)
1. Clean the outer and inner saw blade flange (7a/7b)
carefully, before fitting a new saw blade (7).
2. Clean the reducing ring (7e) and insert it again.
3. Place a new saw blade (7) on the drive shaft (7c).
Observe the rotational direction: The cutting an-
gle of the teeth must point in the running direction
(forwards). The running direction is usually also
marked on the saw blade.
4. Fit the outer saw blade flange (7b) back on the
drive shaft (7c). Ensure the correct alignment of
the outer saw blade flange (7b).
5. Screw the fixing nut (7d) tight onto the drive shaft
(7c) with the hand.
6. Carefully turn the saw blade (7) in the running di-
rection: It must be precisely centred and must not
"wobble". Check that the saw blade (7) and the
outer saw blade flange (7b) are correctly seated.
Re-align the parts if the saw blade is not exactly
centred.
m WARNING
Warning against unexpected hazards and damag-
es to the product
- Check the setting of the saw blade after every
saw blade replacement.
7. Hold the outer saw blade flange (7b) in place with
the 22 mm open end spanner (f).
8. Tighten the fixing nut (7d) clockwise with the 22
mm spanner (f).
9. Mount the table inlay (5) and the saw blade guard
(8) (see 9.3.3 and 9.4.1).
10. Check the correct setting of the riving knife (see
9.3.2).

15.5 Service information

With this product, it is necessary to note that the fol-
lowing parts are subject to natural or usage-related
wear, or that the following parts are required as con-
sumables.
Wearing parts*:Carbon brushes, table inlay, push
stick, saw blade
* may not be included in the scope of supply!

16. Storage

m WARNING
Danger of injury due to unexpected start-up of the ma-
chine
- Pull the mains plug out of the outlet.
ATTENTION
Product damage due to incorrect storage
- Store the product protected against dirt, dust and
moisture.
- Store the product in its original packaging.
1. Store the product in a dark, dry and frost-free
place that is inaccessible to unauthorised persons.
 www.scheppach.com /  service@scheppach.com /  +(49)-08223-4002-99 /  +(49)-08223-4002-58
2. The optimum storage temperature lies between 5
and 30 °C.
3. Store the operating manual with the product.

17. Electrical connection

The electrical motor installed is connected and
ready for operation. The connection complies
with the applicable VDE and DIN provisions. The
customer's mains connection as well as the ex-
tension cables used must also comply with these
regulations.
• The product meets the requirements of EN 61000-
3-11 and is subject to special connection conditions.
This means that use of the product at any freely se-
lectable connection point is not allowed.▪Given un-
favorable conditions in the power supply the prod-
uct can cause the voltage to fluctuate temporarily.
• The product is intended solely for use at connec-
tion points that
a. do not exceed a maximum permitted supply im-
pedance "Zmax = 0.345 Ω", or
b. have a continuous current-carrying capacity of
the mains of at least 100 A per phase.
• As the user, you are required to ensure, in consulta-
tion with your electric power company if necessary,
that the connection point at which you wish to oper-
ate the product meets one of the two requirements,
a) or b), named above.
17.1 Damaged electrical connection cable
The insulation on electrical connection cables is often
damaged.
This may have the following causes:
• Pressure points, where connection cables are
passed through windows or doors
• Kinks where the connection cable has been improp-
erly fastened or routed
• Places where the connection cables have been cut
due to being driven over
• Insulation damage due to being ripped out of the
wall outlet
• Cracks due to the insulation ageing
Such damaged electrical connection cables must not
be used and are life-threatening due to the insulation
damage.
Check the electrical connection cables for damage
regularly. Ensure that the connection cables are dis-
connected from electrical power when checking for
damage.
Electrical connection cables must comply with the ap-
plicable VDE and DIN provisions. Only use connec-
tion cables of the same designation.
The printing of the type designation on the connection
cable is mandatory.
GB | 43