Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Data; Ambient Conditions - Balluff BCM R15E-00 DI00 S4 Serie Betriebsanleitung

Condition monitoring sensor
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

BCM R15E-00 _ -DI00-_ _ , _-S4
Condition Monitoring Sensor
7

Technical data

7.1
General data
Function
Vibration velocity
Vibration acceleration
Vibration severity zones
Contact temperature
Relative humidity
Ambient pressure
Sensor self-awareness
Approval/Conformity
CE
7.2
Functional safety
MTTF (40 °C)
7.3
Detection range/Measuring range
Contact temperature
Measuring range
Resolution
Measurement error
Non-linearity
Settling time
Relative humidity
1), 2)
Measuring range
Resolution
Non-linearity
Settling time
Ambient pressure
1)
Measuring range
Resolution
Non-linearity
Vibration (general)
Frequency range
Sampling rate
Measuring principle
No. of measurement axes
www.balluff.com
1)
1)
239 a
0...70 °C
0.1 °C
±2% FS
±0.75% FS
5 min
5...95% RH
1% RH
±2.5% FS
5 min
300...1100 hPa
0.15 hPa
±0.1% FS
2...3200 Hz
6400 Hz
MEMS
3
Vibration velocity
RMS measuring range
RMS resolution
RMS measurement error
RMS Non-linearity
Evaluation variables (per
measurement axis)
Vibration acceleration
RMS measuring range
RMS resolution
RMS measurement error
RMS Non-linearity
Evaluation variables (per
measurement axis)
7.4

Ambient conditions

Ambient temperature
Storage temperature
Relative humidity
Degree of protection
only for the BCM R15E-002-DI00-_ _ , _-S4
1)
not evaluated by UL
2)
at 79.4 Hz
3)
4)
only for BCM R15E-001-DI00-_ _ , _-S4
0...220 mm/s
3)
0.42 mm/s
3)
±5% FS
3)
±2% FS
3)
RMS
Peak to peak
Mean
Standard deviation
Crest factor
Skewness
Kurtosis
0...16 g
0.006 g
3)
±5% FS
3)
±2% FS
3)
RMS
Peak to peak
0...70 °C
–20...+70 °C
≤ 95 %,
non-condensing
IP67
2)
IP68
2), 4)
IP69K
2), 4)
english
43

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis